header
KSES TYPE EMERGENCY VENT COVER

KSES TYPE EMERGENCY VENT COVER

  •   11/03/2021 12:54:00 PM
  •   Viewed: 903
  •   Feedback: 0

According to API 2000 Code :

The series KSES is designed to provide emergency pressure relief for storage tanks when exposed to overpressures that are not handled by standard tank vents.
These vents provide the capacity to meet API standard 2000 for emergency venting due to fire exposure when properly sized.


 

Vent Operation :

The KSES emergency pressure relief vent provides pressure relief only.
Vacuum relief must be supplied by normal venting devices, or use our KSESV emergency pressure and vacuum relief vent covers.
When excessive pressure builds within the storage tank the KSES series emergency pressure relief vent begin to open at a predetermined set pressure relieving excessive pressure.
When the overpressure has dissipated the cover reseat onto the base.


Construction :

The series KSES is available in several materials that are corrosion resistant to most petroleum product applications.
See Standard material of construction table for available material.
Predetermined setting range is from a minimum of 700mm W.C to a maximum of 7,000mmW.C
Sizes are 400, 450, 500 and 600mm with flange drilling according to ANSI 150lb or API650

KSESV TYPE EMERGENCY VENT COVER

KSESV TYPE EMERGENCY VENT COVER

  •   11/03/2021 12:56:00 PM
  •   Viewed: 809
  •   Feedback: 0

According to API 2000 Code :

The series KSESV is designed to provide emergency pressure vacuum relief for storage tanks when exposed to overpressures and overvacuum that are not handled by standard tank vents.
These vents provide the capacity to meet API standard 2000 for emergency venting due to fire exposure when properly sized.


 

Vent Operation :

The KSES emergency pressure relief vent provides pressure and vacuum relief..
When excessive pressure builds within the storage tank the KSESV series emergency pressure relief vent begin to open at a predetermined set pressure relieving excessive pressure.
When the overpressure has dissipated the cover reseat onto the base.


Construction :

The series KSESV is available in several materials that are corrosion resistant to most petroleum product applications.
See Standard material of construction table for available material.
Predetermined pressure setting range is from a minimum of 700mm W.C to a maximum of 7,000mmW.C and vacuum setting range is from a minimum of -20 mmW.C to maximum of
-700 mmW.C.
Sizes are 400, 450, 500 and 600mm with flange drilling according to ANSI 150lb or API650.

KSEV TYPE EMERGENCY VENT COVER

KSEV TYPE EMERGENCY VENT COVER

  •   11/03/2021 12:58:00 PM
  •   Viewed: 1082
  •   Feedback: 0

According to API 2000 Code :

The series KSEV is designed to provide emergency pressure vacuum relief for storage tanks when exposed to over pressures and over vacuum that are not handled by standard tank vents.
These vents provide the capacity to meet API standard 2000 for emergency venting due to fire exposure when properly sized.
These covers also provide quick easy access for tank inspection and maintenance.


 

Vent Operation :

The KSEV emergency pressure relief vent provides pressure vacuum relief .
When excessive pressure builds within the storage tank the KSEV series emergency pressure relief vent begin to open at a predetermined set pressure relieving excessive pressure.
When the overpressure has dissipated the cover reseat onto the base.


Construction :

The series KSEV is available in several materials that are corrosion resistant to most petroleum product applications.
See Standard material of construction table for available material.
Predetermined pressure / vacuum setting range is from a minimum of 25/-25mmW.C to a maximum of 700/-700mmW.C
Sizes are 400, 450, 500 and 600mm with flange drilling according to ANSI 150lb or API650.

KSEVK TYPE EMERGENCY VENT COVER

KSEVK TYPE EMERGENCY VENT COVER

  •   11/03/2021 12:59:00 PM
  •   Viewed: 869
  •   Feedback: 0

According to API 2000 Code :

The series KSEVK is designed to provide emergency pressure vacuum relief for storage tanks when exposed to over pressures and over vacuum that are not handled by standard tank vents.
These vents provide the capacity to meet API standard 2000 for emergency venting due to fire exposure when properly sized.
These covers can also be easily lifted open, providing a large, unobstructed passage for rapid entry and quick easy access to the tank for tank inspection and maintenance


 

Vent Operation :

The KSEVK emergency pressure relief vent provides pressure vacuum relief .
When excessive pressure builds within the storage tank the KSEVK series emergency pressure relief vent begin to open at a predetermined set pressure relieving excessive pressure.
When the overpressure has dissipated the cover reseat onto the base.


Construction :

The series KSEVK is available in several materials that are corrosion resistant to most petroleum product applications.
See Standard material of construction table for available material.
Predetermined pressure / vacuum setting range is from a minimum of 25/-25mmW.C to a maximum of 700/-700mmW.C
Sizes are 400, 450, 500 and 600mm with flange drilling according to ANSI 150lb or API650.

KSEPK TYPE EMERGENCY VENT COVER

KSEPK TYPE EMERGENCY VENT COVER

  •   11/03/2021 01:00:00 PM
  •   Viewed: 1781
  •   Feedback: 0

According to API 2000 Code :

The series KSEPK is designed to provide emergency pressure relief for storage tanks when exposed to overpressures that are not handled by standard tank vents.
These vents provide the capacity to meet API standard 2000 for emergency venting due to fire exposure when properly sized.
These covers also provide quick easy access for tank inspection and maintenance.


 

Vent Operation :

The KSEPK emergency pressure relief vent provides pressure relief only.
Vacuum relief must be supplied by normal venting devices, or use our KSEV emergency pressure and vacuum relief vent covers.
When excessive pressure builds within the storage tank the KSEPK series emergency pressure relief vent begin to open at a predetermined set pressure relieving excessive pressure.
When the overpressure has dissipated the cover reseat onto the base.


Construction :

The series KSEPK is available in several materials that are corrosion resistant to most petroleum product applications.
See Standard material of construction table for available material.
Predetermined setting range is from a minimum of 50mm W.C to a maximum of 700mmW.C
Sizes are 400, 450, 500 and 600mm with flange drilling according to ANSI 150lb or API650.

KSEPR/EPS TYPE EMERGENCY VENT COVER

KSEPR/EPS TYPE EMERGENCY VENT COVER

  •   11/03/2021 01:03:00 PM
  •   Viewed: 925
  •   Feedback: 0

According to API 2000 Code :

The series KSEPR/EPS is designed to provide emergency pressure relief for storage tanks when exposed to overpressures that are not handled by standard tank vents.
These vents provide the capacity to meet API standard 2000 for emergency venting due to fire exposure when properly sized.
These covers also provide quick easy access for tank inspection and maintenance.


 

Vent Operation :

The KSEPR/EPS emergency pressure relief vent provides pressure relief only.
Vacuum relief must be supplied by normal venting devices, or use our KSEV emergency pressure and vacuum relief vent covers.
When excessive pressure builds within the storage tank the KSEPR/EPS emergency pressure relief vent begin to open at a predetermined set pressure relieving excessive pressure.
When the overpressure has dissipated the cover reseat onto the base..


Construction :

The series KSEPR/EPS is available in several materials that are corrosion resistant to most petroleum product applications.
See Standard material of construction table for available material.
The KSEPR is a weighted pallet model designed to handle pressure with a minimum pressure of 20mmW.C and a maximum setting of 700mmW.C
The KSEPS is a spring loaded model designed to handle pressure with a minimum pressure of 700mmW.C and a maximum setting of 7,000mmW.C



KSEPW TYPE - EMERGENCY VENT COVER

KSEPW TYPE - EMERGENCY VENT COVER

  •   15/08/2022 01:11:36 AM
  •   Viewed: 756
  •   Feedback: 0

The model KSEPW is designed to provide emergency pressure relief for storage tanks when exposed to overpressures that are not handled by standard tank vents. These vents provide the capacity to meet API standard 2000 for emergency venting due to fi re exposure when properly sized. And it provides quick easy access for tank inspection and maintenance. And also designed to be Cushioned Air Seating, Tefl on(FEP+PTFE) diaphragm are standard. The excessive pressure over 75% of set point builds up to 90% of set point, the Liquid (Silicon oil) catch up the Leakage and meet bubble tight (no leakage) at 90% of set pressure. It is designed to be self closing under normal operation by inside Guide and the restraining cables to connect the Cover A'ssy and Flange.


 

The model KSEPW is designed to provide emergency pressure relief for storage tanks when exposed to overpressures that are not handled by standard tank vents. These vents provide the capacity to meet API standard 2000 for emergency venting due to fi re exposure when properly sized. And it provides quick easy access for tank inspection and maintenance.


And also designed to be Cushioned Air Seating, Tefl on(FEP+PTFE) diaphragm are standard. The excessive pressure over 75% of set point builds up to 90% of set point, the Liquid (Silicon oil) catch up the Leakage and meet bubble tight (no leakage) at 90% of set pressure. It is designed to be self closing under normal operation by inside Guide and the restraining cables to connect the Cover A'ssy and Flange.



KSEPKJ TYPE - EMERGENCY VENT COVER

KSEPKJ TYPE - EMERGENCY VENT COVER

  •   15/08/2022 01:14:34 AM
  •   Viewed: 718
  •   Feedback: 0

The model KSEPKJ is designed to provide emergency pressure relief for storage tanks when exposed to overpressures that are not handled by standard tank vents. These vents provide the capacity to meet API standard 2000 for emergency venting due to fi re exposure when properly sized. These covers also provide quick easy access for tank inspection and maintenance.


 

The model KSEPKJ is designed to provide emergency pressure relief for storage tanks when exposed to overpressures that are not handled by standard tank vents. These vents provide the capacity to meet API standard 2000 for emergency venting due to fi re exposure when properly sized. These covers also provide quick easy access for tank inspection and maintenance.

 

You did not use the site, Click here to remain logged. Timeout: 60 second